66GF-63 (serv.man5). 1 - Text (1-9) - Sharp TV Service Manual (repair manual). Page 4

Read Sharp 66GF-63 (serv.man5) Service Manual online

4
66GF-63H
IMPORTANT SERVICING NOTES
Only qualified service personnel are allowed to carry out maintenance and repair of this receiver.
SERVICING OF HIGH VOLTAGE SYSTEM AND CRT
It is important that the static charge is removed from the high voltage system when carrying out work
on the receiver. This can be achieved by connecting a 10K resistor (with a suitably insulated lead) from
the CRT cavity connector to the CRT ground tag. This must be carried out with the AC supply discon-
nected from the receiver.
Note the following:
 The CRT in this receiver employs Integral Implosion Protection.
 If the CRT has to  be changed  it  MUST  be  replaced  with  the  correct  type for continued safe
working
 DO NOT lift the CRT by its neck.
 When handing the CRT, ensure that shatterproof goggles are worn.
 Ensure that the CRT is discharge before handling.
X-RAY
This receiver is designed to keep any x-ray emission to an absolute minimum. Some fault conditions
and servicing procedures may produce potentially hazardous x-ray radiation levels. This is a problem
when in close proximity to the receiver for long  periods of time. To reduce any risks associated with
this, please observe the following precautions:
1. When undertaking any servicing on this chassis, DO NOT increase the EHT  to more than 33 KV,
   (at a instantaneous beam current of 1800
µΑ).
2. Ensure that during normal operation the EHT does not exceed 32KV
±
1.5KV (at a beam current of
   1600
µΑ). This level has been preset in the factory. Always check that this level has not been ex-
ceeded
   after carrying out any repair on the receiver..
3. DO NOT replace the CRT with any other type than that specified in the parts listing as this may
   cause excessive x-ray radiation.
BEFORE RETURNING THE RECEIVER TO THE CUSTOMER
In addition to the above checks, the following should also be carried out before  returning the receiver
to the customer.
1. Inspect all the leads to ensure that they are dressed correctly and that they are not obstructed or
    pinched by any other parts.
2. Ensure that all protective devices are in good condition. These will include nonmetallic control
   knobs, insulating fish papers, cabinets backs, compartment covers or shields, mechanical insulators,