66DW-18H (serv.man35). Fitting instructions for Thomson CRT - Sharp TV Technical Bulletin (repair manual). Page 2

Read Sharp 66DW-18H (serv.man35) Technical Bulletin online

Sharp Electronics (UK) Limited
Originator AvW   Supervisor                        Approval Date    /   /     Reference SP84001X
Revision 2
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
CTV990107
Month of Issue:    January 1999
        Classification:                   White
TELEVISION TECHNICAL BULLETIN
Page 2 of 3
THOMSON PICTURE TUBE
                                                                                                       Red          Orange       Yellow                Green
                                                                                                          FH lead                       FV lead
To change the deflection yoke wiring from a Philips CRT to a Thomson CRT, proceed as
follows.
1.  Unsolder the red and orange FH leads from the deflection yoke.
2.  Remove connector 1 from the yellow and green leads.
3.  Strip the yellow and green wires of insulation (about 4mm).
4.  Solder the red and orange (FH) leads as shown above.
5.  Solder the yellow and green (FV) leads as shown above.
6. Replace 
lead 
KC 
(QCNW-2757BMZZ) connects the CRT socket to the neck of the CRT
with QCNW-2775BMZZ type.
FV
FH
KC lead
Page of 3
Display