51GT-25 (serv.man2). - Part 1 - Text (1-11) - Sharp TV Service Manual (repair manual). Page 6

Read Sharp 51GT-25 (serv.man2) Service Manual online

6
51GT-25H
Adjustment of Data within the NVM memory
To access the NVM memory, press the channel up button on the remote control until the NVM setting is
         reached. Note that the NVM address is shown in green and the NVM value is shown in red.
         Each of the NVM values are stored as a hexadecimal code, each code comprises of two hexadecimal
         numbers. Each of these numbers will break down into bit four binary code as in the example below.
Hex code     
                                     
A
         5
Binary code                                1010               0101
Button on remote to toggle Bit    7654              3210
         In the example given above, the hexadecimal code is A5, the binary equivalent is 1010 0101. The remote
         control button to toggle each bit on or off (1 or a 0) is shown below the binary code. Therefore to change this
         to A6, remote control buttons 1 then 0 would have to be pressed.
NVM LIST DESCRIPTION
PAGE
ADDRESS
DESCRIPTION
VALUE
00
RTEMP: TEMPERATURE RED
15
01
GTEMP: TEMPERATURE GREEN
0E
02
BTEMP : TEMPERATURE BLUE
0C
03
VSHIFT: VERTICAL SHIFT
27
04
HSHIFT: HORIZONTAL SHIFT
1C
05
VTAMP: VERTICAL AMPLITUDE
36
06
VSLOPE: VERTICAL SLOPE
10
07
Y_DELAY: LUMA DELAY
08
08
Y_DELAY_S: LUMA DELAY SECAM
08
09
S_CORR: S-CORRECTION
00
0A
E_CAG : CAG ADJUSTEMENT VALUE
00
0B
EA_OPT: TV OPTIONS
0: FP: SYSTEM B/G (0)- B/G+L, MESSAGE RECHERCHE
1: AV FRONTAL: NOT INCLUDED(0), INCLUDED(1)
2: TUNING LOCK (HOTEL): LOCKED+SWITCH-ON PR1(1)
                                              NO LOCKED (0)
3: UHF-ONLY: BAND UHF(1) ALL BANDS(0)
4: PAL ONLY(1), PAL+ SECAM(0)
5: CHILD LOCK: CHILD LOCK ACTIVE(1)
                           CHILD LOCK NO ACT(0)
6: AUTO FIRST: TUNING FIRST MENU: AUTO (1)
                                                                 MANUAL (0)
7: ING_OSD: OSD_ENGLISH(1)  OSD-SYMBOL(0)
F8
0C
EAFT: AFT ADJ FOR  B/G & L SYSTEMS
40
0D
EAFT_: AFT ADJ FOR L' SYSTEMS
1F
0E
EVOLMAX: MAX. VOLUME LIMIT
FF
0F
CHECKSUM: SIGNATURE
A5
10
RTEMP2: TEMPERATURE RED
15
11
GTEMP2: TEMPERATURE GREEN
0E
12
BTEMP2: TEMPERATURE BLUE
0C
13
VSHIFT2: VERTICAL SHIFT
27
14
HSHIFT2: HORIZONTAL SHIFT
1C
15
VTAMP2: VERTICAL AMPLITUDE
36
16
VSLOPE2: VERTICAL SLOPE
10
17
Y_DELAY2: LUMA DELAY
08
0
18
Y_DELAY_S2: LUMA DELAY SECAM
08