XV-Z91E (serv.man10). Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 9

Read Sharp XV-Z91E (serv.man10) Service Manual online

29
XV-Z90E
» 
Formatter Unit Troubleshooting -1/2
Abnormal picture
No
Yes
Rainbow-like colors on-
screen.
No proper matching in 
red, green and blue.
Adjustments made on 
"PROCESS MENU"
"DLP"
"INDEX", but 
correction impossible.
Blackout
Are connections made 
properly with the 
SC9101 and SC9001 
sockets?
Is the color wheel 
running?
IC9101, IC9102 or their 
peripheral circuit, or 
color wheel defective.
Thick, white vertical 
stripes (flashing).
No
Others
IC9003, IC9004, IC9006 
or their peripheral circuit 
defective.
Is connection made 
properly with the 
SC9001 socket?
No
Is the voltage at pin (3) 
of IC9007 as specified 
(+2.5V)?
Yes
Yes
Are there 400-MHz 
sine-wave signals at 
pins (18) and (20) of 
IC9001?
Are there dust deposits on 
DMD, formatter board and 
cLGA contact terminal?
No
Refit the DMD, optical 
mechanism and formatter 
board PWB.
Yes
IC9001 or its peripheral 
circuit defective.
Yes
No
No
Is the specified voltage 
applied to the P9002 
connector?
Yes
IC9003 and/or IC9004 
defective.
Check the main PWB 
and power unit.
Yes
No
Is the voltage at the 
positive-polarity pin of 
C9308 as specified 
(+5V)?
Yes
IC9301 or its peripheral 
circuit defective.
No
Is there 150-Hz pulse 
signal at pin (2) of 
P9003 with no signal 
input?
Yes
Check the color wheel 
sensor PWB.
No
Is the voltage at pin (9) 
of IC9301 as specified 
(+23 to +26V)?
Yes
No
Is the voltage at pin (13) 
of IC9301 as specified 
(-26V)?
Yes
IC9301 or its peripheral 
circuit defective.
No
Is the voltage at pin (49) 
of IC9301 as specified 
(+7V)?
Yes
No
Is a lamp turned on?
Yes
5
6
Page of 10
Display