Read Sharp XV-Z21000 (serv.man4) Service Manual online
XV-Z20000/XV-Z21000/DT-5000
4 – 3
Do not change the process adjustment values other than the above since they are set so that optimal images are obtained.
6-4
Component RGB-gain adjust-
ment
(Auto adjustment)
ment
(Auto adjustment)
1. Adjustment device: AD998417
2. Adjustment group: AD (COMP) (Process
gamma linkage)
3. Adjustment item: G-D
Initial value: 70
4. Input terminal: DVI A-Component
(Input switching linkage)
5. Component wind pattern having 100%
(0.7 Vpp) G signal and 0%
6. Perform adjustment after adjusting CR-
OFFSET, CB-OFFSET and G-BRIGHT.
2. Adjustment group: AD (COMP) (Process
gamma linkage)
3. Adjustment item: G-D
Initial value: 70
4. Input terminal: DVI A-Component
(Input switching linkage)
5. Component wind pattern having 100%
(0.7 Vpp) G signal and 0%
6. Perform adjustment after adjusting CR-
OFFSET, CB-OFFSET and G-BRIGHT.
1. Observe the 100% portion.
2. Vary G-GAIN (decrement direction), and the illumi-
nance and chromaticity start to change.
3. Adjust to the point raised by 2 points from the point
where bit dropout appears on the screen.
2. Vary G-GAIN (decrement direction), and the illumi-
nance and chromaticity start to change.
3. Adjust to the point raised by 2 points from the point
where bit dropout appears on the screen.
7
White balance adjustment
1. Adjustment device: DDP3021
2. Adjustment group: DLP
3. Adjustment item: R-GAIN
Initial value: 95
B-GAIN
Initial value: 95
4. Input terminal: DVI A-Component
(Input switching linkage)
5. Input signal: Component 75% gray signal
2. Adjustment group: DLP
3. Adjustment item: R-GAIN
Initial value: 95
B-GAIN
Initial value: 95
4. Input terminal: DVI A-Component
(Input switching linkage)
5. Input signal: Component 75% gray signal
1. Observe the chromaticity of 75% portion using
CL200.
2. Adjust the y value to adjustment chromaticity
CL200.
2. Adjust the y value to adjustment chromaticity
±
0.005 with B-GAIN.
3. Adjust the x value to adjustment chromaticity
3. Adjust the x value to adjustment chromaticity
±
0.005 with R-GAIN.
Adjustment chromaticity
x = 0.299
Adjustment chromaticity
x = 0.299
±0.005
y = 0.316
±0.005
8
Factory setting
1. Group: SSS
1. Perform the following settings.
Destination Process adjustment Remote control
setting
Europe: S3 Factory setting 3
North America: S4 Factory setting 4
Japan: S5 Factory setting 5
China: S6 Factory setting 6
South America: S7 Factory setting 7
Destination Process adjustment Remote control
setting
Europe: S3 Factory setting 3
North America: S4 Factory setting 4
Japan: S5 Factory setting 5
China: S6 Factory setting 6
South America: S7 Factory setting 7
No.
Adjusting point
Adjusting conditions
Adjusting procedure