Replacing the DMD Chip
Version 1.4
Issue 09/2006
40
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
* Precautions in setting up the DMD (Digital Micromirror Device) unit
Before connecting the formatter PWB to the optical engine, take the following steps. Look at
the voltage rank marking that is on the DMD itself. Referring to this marking, set the DIP
switches on the formatter PWB. And connect this PWB to the optical engine. Wrong settings
will adversely affect the system performance.
DMD Setting: Check the last alphabet character shown in 1, and set the two switches shown
in 2 according to the configurations shown in 3. Set the formatter PWB switches according to
the Bin voltage shown on the back face of the DMD.
Voltage ranking system with the switch switches on formatter PWB