XV-Z200E (serv.man13). Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 6

Read Sharp XV-Z200E (serv.man13) Service Manual online

36
XV-Z200U/E, XV-Z201E
DT-300
Feed the composite video signal to 
INPUT 4. Select INPUT 4 using the 
set's key or the remote controller.
Does the picture appear?
Is the picture disturbed?
End.
Is the picture signal inputted to the 
connector TC (9) pin?
Yes
Yes
No
No
Yes
Check the TERMINAL2 PWB.
No
Is the picture signal inputted to the 
pin (1) of IC3105?
Yes
Check the VIDEO-IN signal 
line of IC3503.
No
Is input coming to pins (1), (3) and (5) of IC3104?
Yes
Check IC3102 peripheral circuits.
No
Is output coming from pins (16), (18) and (20) of IC3104?
Yes
Check IC3104 peripheral circuits.
No
Is the picture signal inputted to pins (43), (48) and (54) of
IC6004 and the synchronized signal inputted to pins (30)
and (31)?
Yes
Check around IC3104, IC6001 and IC6002.
No
Is each digital output coming on pins (64), (65), (66) and
(67) of IC6004?
Yes
Check IC6004 peripheral circuits.
No
Is output coming from IC8001, DPORT?
Check the formatter PWB.
Yes
Check IC8001 peripheral circuits.
No
Is it N358 signal?
No
Check around IC3501, 3505.
Yes
Is it PAL?
No
Check around IC3504, 3506.
Yes
Is it SECAM?
Check the color system, around IC3105. Others.
No
Check around IC 3105. 
Malfunction of the color 
system is thinkable.
Yes
Checking of Video Input
Check IC3102 peripheral 
circuits.
1
3
No
Yes
Is synchronized signal 
coming to pins (28) and 
(29) of IC3102?
2
Memo
In case of N358, Y/C separates at IC3505 3 DY/C and inputted 
to IC3105 (5) (7) pins.
In case of PAL system, Y/C separates at IC3506 3 Line COM 
and inputted to (39) (41) of IC3105.
The video is outputted from (21) (22) (23) at color difference 
from IC3105.
Page of 9
Display

Click on the first or last page to see other XV-Z200E (serv.man13) service manuals if exist.