35
XV-Z200U/E, XV-Z201E
DT-300
Checking of SOG Circuit
Measure the pin (7) of IC5012 
with an oscilloscope.
This is the failure of the SOG 
synchronization separator circuit.
Is there the Y signal including sync 
signal?
Measure the pin (7) of IC5010 
with an oscilloscope.
Is the composite synchronized 
signal regenerated at proper timing?
No
Is there output of the pin (25)
of IC3102?
No
The SOG circuit is normal. 
End.
Yes
Yes
Yes
Check around Q5002.
No
Input the S terminal (Y, C) signal to 
INPUT 3. Select INPUT 3 with the 
keys on the main body or the 
remote controller.
Is the signal N358?
Does the picture appear?
Is the picture disturbed?
End.
Is the picture signal inputted to the 
pins (5) and (7) of connector TC?
Yes
No
No
No
No
Yes
No
In the picture signal inputted to 
pins (43) and (44) of IC3105?
Yes
Check the input side PWB .
Check IC3505 and the 
peripheral circuits of the IC.
Yes
Yes
Check of the S terminal input.
Check the Y, C signal 
lines.
Check IC3105 and the 
peripheral circuits of the 
IC.