Read Sharp XV-Z12000 (serv.man11) Service Manual online
No.
Adjusting point
Adjusting conditions
Adjusting procedure
31
XV-Z12000
Background adjustment method
ΙΙΙΙΙ. Adjustment conditions
1) Adjustment item: Process mode,
1) Adjustment item: Process mode,
DLP menu
GAMMA
R-GAIN, G-GAIN, B-GAIN
GAMMA
R-GAIN, G-GAIN, B-GAIN
2) Input signal: Component video 75% white signal
1 With the component video 100% white signal, adjust the output to 0.7 ± 0.05 Vp-p (excluding the synchro-
nous part.) (The sync signal is 0.3 Vp-p.)
2 Next drop the image signal output to 75%.
3 Input the signal to INPUT5 (DVI-I connector).
3 Input the signal to INPUT5 (DVI-I connector).
3) Target adjustment chromaticity
x = 0.290 ± 0.005
y = 0.311 ± 0.005 (Color temperature: 8500K, +6UV)
y = 0.311 ± 0.005 (Color temperature: 8500K, +6UV)
ΙΙ
ΙΙ
ΙΙ
ΙΙ
ΙΙ. Adjustment procedures
1) Select GAMMA from the DLP menu and set the value to “6”. (Initial value = 6)
2) Set R-GAIN, G-GAIN, B-GAIN to “96”. (Initial value = 95)
3) Background adjustment
1) Select GAMMA from the DLP menu and set the value to “6”. (Initial value = 6)
2) Set R-GAIN, G-GAIN, B-GAIN to “96”. (Initial value = 95)
3) Background adjustment
1 Project on a 40-inch screen, and observe the chromaticity in the center with a color meter.
2 Fix G-GAIN to 95.
3 Adjust the x and y values to the target adjustment chromaticity with B-GAIN. However, the adjusted value is
2 Fix G-GAIN to 95.
3 Adjust the x and y values to the target adjustment chromaticity with B-GAIN. However, the adjusted value is
up to 115 at maximum.
4 Adjust the x and y values to the target adjustment chromaticity with R-GAIN. However, the adjusted value is
up to 115 at maximum.
When the R-GAIN value is 115 and the x value cannot be adjusted,
1) Lower the B-GAIN and adjust to x = 0.290.
2) Lower the G-GAIN and adjust to y = 0.331.
When the R-GAIN value is 115 and the x value cannot be adjusted,
1) Lower the B-GAIN and adjust to x = 0.290.
2) Lower the G-GAIN and adjust to y = 0.331.
5 Check that the middle gradation is not greatly deviated.
4) Exit the DLP menu by pressing the UNDO key on the remote control.
Click on the first or last page to see other XV-Z12000 (serv.man11) service manuals if exist.