XV-Z100. Version 1.1 - Sharp Projector Handy Guide. Page 12

Read Sharp XV-Z100 Handy Guide online

Lamp Replacement Procedure
Version 1.1
Issue 04/2006
12
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
3. 
 Remove the lamp unit cover.
• 
Turn the projector over. Loosen the user service screw (1) that secures
the lamp unit cover. Pressing the tab, remove the lamp unit cover (2).
4. 
 Remove the lamp unit.
• 
Loosen the securing screws from the lamp unit. Hold the lamp
unit by the handle and pull it in the direction of the arrow. 
5. 
Insert the new lamp unit.
• 
Press the lamp unit firmly into the lamp unit compartment.
Fasten the securing screws.
 
6. 
 Replace the lamp unit cover.
• 
Align the tab on the filter/lamp unit cover (1) and place it while
pressing the tab (2) to close it. Then tighten the user service
screw (3) to secure the filter/ lamp unit cover.
Note
• 
If the lamp unit and lamp unit cover is not correctly installed, the power will not turn on,
even if the power cord is connected to the projector.