XR-20S (serv.man14). Trouble shooting - Sharp Projector Service Manual (repair manual). Page 7

Read Sharp XR-20S (serv.man14) Service Manual online

36
XR-10X/S
XR-20X/S
NO
Securely insert the 
connectors.
YES
Check the cooling fan.
NO
Check peripheral circuits of 
Q1721.
NO
Check IC1761, IC3581 and 
peripheral circuits.
NO
Go to "DMD system check".
Is 3.3 V applied to TL1762?
NO
Check IC1791 and 
peripheral circuits.
NO
Check PHOTO SENSOR 
PWB.
NO
Check IC1701 and 
peripheral circuits.
NO
Check IC1762 and 
peripheral circuits.
YES
Is 5 V applied to TL1712 
with P1703 removed?
NO
Check connection of 
FB1710.
NO
Check when the lamp turns 
off soon after turning on
Have connectors P1703, 
P1721, P1722, P1723 and 
P1724 come off or are they 
loose?
Is each cooling fan 
rotating? 
Is approx. 3 V applied to 
TL1721?
YES
Is 12 V applied to TL1761?
YES
Is 2.5 V applied to 
TL1763?
YES
Check IC1763 and 
peripheral circuits.
NO
Is 5 V applied to TL1712?
YES
Is the signal of 180 Hz 
sent to TL1716?(When 
vertical frequency of the 
input signal is 60 Hz)
YES
Is the signal of 180 Hz 
sent to TL1706? (When 
vertical frequency of the 
input signal is 60 Hz)
YES
YES
Is 5 V applied to TL1791?
YES
Check the power supply 
ballast PWB.
YES
Page of 9
Display