LV067
Sharp Electronics (UK) Ltd., Technical Services Group
IC2601 REPLACEMENT PROCEDUE
Replace IC2601 with RH-IXA500WJN1Q. (OTP)
Replace IC2601 with RH-IXA500WJN1Q. (OTP)
After replacing IC2601:
You can check the solder failure by performing the following inspection.
• IR remote
You can check the solder failure by performing the following inspection.
• IR remote
Check the projector can receive some signal from IR remote.
• Operation keys
Make sure that all the operation key works well.
• Filter sensor
Removing the filter cover, make sure that the projector won’t turn on. (Power LED blinks
in red.)
in red.)
• LED
Make sure that the power LED lights up in red when the projector is in the standby mode
and then lights up in green when the projector is on.
and then lights up in green when the projector is on.
• Monitor-out
Make sure that the monitor-out will be output when the monitor-out function is on.
• RS232C communication
Make sure that data will be returned by sending an command of “TERM 1”.