XG-V10XE (serv.man37). Vertical lines appearing by repeatedly sending commands - Sharp Projector Technical Bulletin (repair manual). Page 2

Read Sharp XG-V10XE (serv.man37) Technical Bulletin online

LV067
Sharp Electronics (UK) Ltd., Technical Services Group
IC2601 REPLACEMENT PROCEDUE
Replace IC2601 with RH-IXA500WJN1Q. (OTP)
After replacing IC2601:
You can check the solder failure by performing the following inspection.
• IR remote
Check the projector can receive some signal from IR remote.
• Operation keys
Make sure that all the operation key works well.
• Filter sensor
Removing the filter cover, make sure that the projector won’t turn on. (Power LED blinks
in red.)
• LED
Make sure that the power LED lights up in red when the projector is in the standby mode
and then lights up in green when the projector is on.
• Monitor-out
Make sure that the monitor-out will be output when the monitor-out function is on.
• RS232C communication
Make sure that data will be returned by sending an command of “TERM 1”.