XG-V10WE (serv.man8). Service Manual text - Page 1-59 - Sharp Projector Service Manual (repair manual). Page 50

Read Sharp XG-V10WE (serv.man8) Service Manual online

50
XG-V10WE
AN-SD1E/S422E
TROUBLE SHOOTING TABLE FOR PC I/F UNIT-4
Checking the sync signal
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Is there vertical sync signal at 
TL134?
Check up the input signal 
settings.
» 
Check the H/V separation type sync signal.
Is there horizontal sync signal 
at TL133?
Input PWB defective.
Is there vertical sync signal at 
TL131?
Is there horizontal sync signal 
at TL130?
PC board s sync signal 
selector circuit or its 
peripherals defective.
Are both the vertical and 
horizontal sync signals in 
good timing?
No problem with the sync 
signal.
Is the signal generator (input 
source) as specified?
Make proper signal source 
settings.
Input PWB defective.
2
Page of 59
Display

Click on the first or last page to see other XG-V10WE (serv.man8) service manuals if exist.