Replacing the R-LCD panel
(1) Disconnect the LCD flat cable from the output PWB connector.
<Figure 1>
(2) Remove the two screws "A".
(3) Lift and detach the plate "B" together with the incident light deflection plate.
(2) Remove the two screws "A".
(3) Lift and detach the plate "B" together with the incident light deflection plate.
<Figure 2>
(4) Remove the four screws "C" and separate the units D and E from each other.
(5) Take the R-LCD panel out of the adjusting plate.
(6) Place and fix a new R-LCD panel in the reverse steps.
(7) Adjust the deflection plate. (See page 26).
(8) Adjust the focus and convergence. (See page 21.)
(4) Remove the four screws "C" and separate the units D and E from each other.
(5) Take the R-LCD panel out of the adjusting plate.
(6) Place and fix a new R-LCD panel in the reverse steps.
(7) Adjust the deflection plate. (See page 26).
(8) Adjust the focus and convergence. (See page 21.)
~
Readjust the convergence and focus. Note that the G LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction.
a small adjustment range in the Z direction.
R-LCD panel
mounting screws
mounting screws
R adjusting plate
R-LCD
4
A
B
A
D
C
C
E
Fig.1
Fig.2
SIDE VIEW