XG-P25XE (serv.man10). Convergence and focus adjustment - Sharp Projector Service Manual (repair manual). Page 4

Read Sharp XG-P25XE (serv.man10) Service Manual online

XG-P25X
24
Replacing the G-LCD and B-LCD panels
With the top cabinet removed
(1) Disconnect the LCD flat cable from the output PWB connector.
(2) Remove the lock screws "b" and "c". Detach the R/B adjusting plate or the G adjusting plate together with the LCD
panel.
(3) Separate the LCD panel from the adjusting plate.
(4) Mount a new LCD panel in the reverse order of the above steps (1), (2) and (3).
~
Readjust the convergence and focus. Note that the G LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction.
G-LCD panel
mounting screws
Lock 
screws "c"
Lock screws "c"
Lock 
screws "b"
FRONT
2
2
2
SIDE VIEW
TOP VIEW
SIDE VIEW
B-LCD panel
mounting screws
Lock screws "c"
X
Z
θ
Y
X
Y
θ
Z
B adjusting plate
B-LCD
G-LCD
~
R-LCD
B-LCD
X
Z
θ
Y
3
G-LCD
G adjusting plate
3
2
Page of 7