Lamp Replacement Procedure
Version 1.4
Issue 04/2006
12
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
4. 
 Remove the lamp unit cover.
• 
Loosen the user service screw that secures the lamp unit cover.
Then open the cover in the direction of the arrow.
 
5. 
Remove the lamp unit.
• 
Loosen the securing screws from the lamp unit. Hold the
lamp unit by the handle and pull it in the direction of the
arrow. 
6. 
Insert the new lamp unit.
• 
Press the lamp unit firmly into the lamp unit compartment. Fasten
the securing screws. 
7. 
 Attach the lamp unit cover.
• 
Insert the tab of the lamp unit cover into the opening, and press the
cover until it clicks in place. 
Note
• 
If the lamp unit and lamp cover are not correctly installed, the power
will not turn on, even if the power cord is connected to the projector.