Read Sharp XG-NV4SE (serv.man5) Service Manual online
36
XG-NV4SE/SM
XG-NV40SA
XG-NV40SA
TROUBLE SHOOTING TABLE
(Continued)
Checkig the Power Unit
There is no voltage output at
EA connector.
EA connector.
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
Is there any other output
voltage failure?
voltage failure?
Is EA connector disconnected
or loose?
or loose?
Is AC voltage (85-264V)
applied across the PA
connector?
applied across the PA
connector?
Is R724 open?
Is there short-circuit between
collector and emitter of Q702?
collector and emitter of Q702?
Reconnect the EA connector.
Replace F791.
Which output voltage line fails?
Replace F751.
Replace F752.
Replace Q702.
Replace PC702.
Replace IC701, IC702, T701 or
R724.
R724.
4.5V
-7