XG-NV3XE. Service manual supplement - Sharp Projector Service Manual (repair manual). Page 3

Read Sharp XG-NV3XE Service Manual online

3
XG-NV2/20
XG-NV3/30
XG-NV33/330
SUPPLEMENT
2. Attaching the dust filter adjusting legs (for stationary use)
Notes:
»
To attach the legs, use the ceiling-mount fixture lock screw holes of the unit’s bottom.
»
Position the legs with their adjusters facing front.
2-1. Secure the dust filter adjusting legs with the two screws for each.
2-2. Fix the dust filter adjusting leg covers with the four screws for each.
2-2
2-2
2-2
2-1
2-1
2-1
2-1
2-2
3-1
3-1
3-3
3-2
3-4
3-4
3. Replacing the dust filter
3-1. Remove the two lock screws from the air intake cover.
3-2. Take out the old dust filter.
3-3. Place the new dust filter. Refer to the figure for its proper
positioning.
Notes:
»
Install the dust filter with its sides along the sides of the
projector.
3-4. Tighten up the two air intake cover lock screws.
Rear adjusting leg cover
Rear adjusting
leg
Front adjusting leg cover
Front adjusting leg
Air Intake Cover
Dust Filter
Side of Dust Filter