2-4. While pressing the top center at both sides of the bottom cabinet, pull the ends of the top cabinet outward to
unhook it. Slowly lift the back of the top cabinet, disconnect the operation key PWB connector (KY) and the
speaker connector (SP), and take up and away the top cabinet.
2-5. Remove the lock screw off the video terminal cover and detach the video terminal cover.
2. Removing the top and rear cabinets
2-1. Remove the five lock screws off the rear cabinet.
2-2. Remove the ten lock screws from the rear cabinet and the terminal plate. Detach the rear cabinet from the
bottom first (because it is hooked at the top).
2-3. Remove the four lock screws off the top cabinet.
2-3
2-3
2-3
2-1
2-1
2-2
2-2
2-3
2-2
(KY)
(SP)
2-4
2-5
Operation Key Unit
Top Cabinet
Rear Cabinet
Video Terminal Cover