Read Sharp XG-C465X (serv.man4) Service Manual online
XG-C435X/C465X
3 – 9
2. Cautions for 3D color shading correction/adjustment
The following measurement and adjustment must be performed under the same conditions using the following:
• Dark room (Block out stray light.)
• Diffuse reflection (mat type) screen
The setting of the projector must be performed under the following conditions:
• Power save disabled (to keep the lamp stable during measurement)
• Auto search canceled (to fix to INPUT1)
• RGB mode of the input terminal COMPUTER1 (component mode canceled - just to be sure)
1. System setting (“Setting -” System setting””)
Condition setting for C435/C465
2. Teaching
Basically, teaching should be measured only once from model to model. However, if the optical characteristics of the set are changed significantly,
it is necessary to reset the conditions according to changes and to perform remeasurement.
it is necessary to reset the conditions according to changes and to perform remeasurement.
Measurement method of correction factor
1) Determine the standard set of C435/C465. Each one unit (n units)
2) Switch the set to the RGB mode of the input terminal COMPUTER1.
3) Execute teaching of the standard set under the following conditions.
Condition setting for C435/C465
System option
Simultaneous writing of 3D correction value:
Simultaneous writing of 3D correction value:
No (not checked)
Char transmission interval:
0 ms
Binary interval:
2 ms
Creation of correction value by linear correction factor:
No (not checked)
Number of image captures (during adjustment or measurement): Twice
Number of image captures (during teaching):
Number of image captures (during teaching):
4 times
Model name:
Enter the model name newly.
Resolution:
1024 x 768
Binary interval:
2 ms
Correction value, X direction:
33
Correction value, Y direction:
25
Number of correction bits:
8
Adjustment value, minimum:
-32
Adjustment value, center:
0
Adjustment value, maximum:
32
Number of teachings:
5
Teaching interval:
32
Brightness variation direction by adjustment value: Brightness UP by increasing the adjustment value (checked)
Adjustment point:
Adjustment point:
3D (checked)
TG system (selected)
Tone 0 (checked)
Tone 1 (checked)
Other tones are not checked.
TG system (selected)
Tone 0 (checked)
Tone 1 (checked)
Other tones are not checked.
Adjustment point (Test pattern display level)
Tone 0:
Tone 0:
44%
Tone 1:
64%
Adjustment color:
Adjustment with RGB (checked)
Click on the first or last page to see other XG-C465X (serv.man4) service manuals if exist.