XG-C40XE (serv.man15). Service Manual Complete - Sharp Projector Service Manual (repair manual). Page 21

Read Sharp XG-C40XE (serv.man15) Service Manual online

21
XG-C40XU/XE
R-LCD
B-LCD
Lock screw "a"
Lock screw "c"
Notch and 
hole "c"
Notch and 
hole "b"
Lock screw "c"
G-LCD
G-LCD
Lock screw "b"
Notch and hole "c"
Notch and hole "a"
Lock screw "d"
Lock screw "d"
R·B-LCD panel 
mounting screws
(four screws)
R·B-LCD
SIDE VIEW (from inside)
SIDE VIEW (from outside)
TOP VIEW
SIDE VIEW
G-LCD panel 
mounting screws
Eccentric cam
(Y direction adjustment)
Eccentric cam
(X direction adjustment)
Eccentric cam
(
θ
Z direction adjustment)
(four screws)
4. With the G-LCD panel's screen center as refernce, adjust the R-LCD and B-LCD panels.
5. Finally tighten up the convergence lock screw "d".
Notes :
1
The eccentric cam is used for convergence adjustment.
This means that the cam's turning and the linear movement are not always uniform.
2
This model is not equipped with the LCD image adjustment mechanism. This is because the cross-dichroic
prism is used for image formation. When the LCD panels all get into best focus, the images are almost
completely converged.
Convergence and Focus Adjustments Mechanism
Page of 115
Display

Click on the first or last page to see other XG-C40XE (serv.man15) service manuals if exist.