Read Sharp PG-MB60X (serv.man12) Service Manual online
30
PG-MB60X
No.
Adjusting point
Adjusting conditions
Adjusting procedure
30
Delivery set-
tings
tings
1. Make the following settings.
Destination
Process
Remote control
adjustment
adjustment
USA
SS4
Factory setting at 4
China
SS6
Factory setting at 6
Europe and
the Other
SS3
Factory setting at 3
Contries
Calling and quitting the process mode with the control keys on this model.
∗
Although it is possible for the process OUT to exit using the process menu, the IN/OUT toggle command is also
available considering the existing specification.
available considering the existing specification.
1. Calling and quitting
With the menu not displayed, press the "ENTER", "ENTER", "VOL+", "VOL-", "ENTER", "ENTER" and "MENU"
keys on main unit.
keys on main unit.
2. Others
Press the S3563 process key (toggle) on the main PWB to call and quit the process menu.
Note: When adjusting in the process mode, set a signal with a vertical frequency of 60 Hz or no signal. (May not be
properly adjusted with other signals.)
Resetting the lamp timer for this model
1. Resetting procedure
In Stand-by, run this command to clear the operating time of the lamp to 0 and turn on the power.
Press and hold "DOWN", "ENTER", and "MENU", and then press the "ON" key of the set.
Press and hold "DOWN", "ENTER", and "MENU", and then press the "ON" key of the set.
Forced disabling of the System-Lock of this model
1. Disabling procedure
With System-Lock input window onscreen, press the "MENU", "ENTER", "ENTER", "MENU", "ENTER", "ENTER"
and "MENU" keys, in this order, on the remote controller.
and "MENU" keys, in this order, on the remote controller.
1. Connect to a PC with a
USB cable.
1. Check that advance/reverse operation on PC screen
is possible by using remote control.
29
USB operation
check
check