Read Sharp PG-MB60X (serv.man12) Service Manual online
29
PG-MB60X
No.
Adjusting point
Adjusting conditions
Adjusting procedure
21
Adjustment of
DLP voltage
DLP voltage
1. Read voltage rank of DLP
description.
2. Set the switch correspond-
ing to the rank which has
been read.
been read.
1. Carry out adjustment when DLP chip has been re-
placed or combination of chip and formatter has been
changed.
Rank:
changed.
Rank:
B C D E
Setting value: 1 2 3 4
Adjustment when assembling
No.
Adjusting point
Adjusting conditions
Adjusting procedure
23
Adjustment of
DLP Brightness
DLP Brightness
1. Select the following group
and subject.
Group : DLP
Subject : R-Bright
Group : DLP
Subject : R-Bright
G-Bright
B-Bright
B-Bright
1. Check the fixed value.
Fixed value
: 32
Checkpoints
24
RGB tone
reproduction
adjustment
reproduction
adjustment
1. Make sure the 100% and 95% white as well as the
0% and 5% black gradations are visible.
1. Feed the SMPTE pattern
signal.
25
White balance
checking and
readjustment
checking and
readjustment
1. RGB Inputt, sRGB Input,
DTV Input, DVD Input,
VIDEO Input
VIDEO Input
Check that there is no deviation of white balance with
the monitor.
the monitor.
1. Select OFF from the process mode.
Make sure the off-timer starts with 5 minutes
onscreen and count one minute in one second.
And then indication is 0 minute, the power supply
of the set is cut off.
onscreen and count one minute in one second.
And then indication is 0 minute, the power supply
of the set is cut off.
26
Off-timer per-
formance
formance
1. Heat the thermistor with a
hair dryer.
1. Make sure that the temperature is indicated.
27
Thermistor
performance
checking
performance
checking
1. Feed the phase check pat-
tern signal.
1. In the VGA, SVGA, XGA and SXGA modes, make
sure the Clock, Phase, H-Pos and V-Pos settings
can be automatically adjusted.
can be automatically adjusted.
28
Auto sync
performance
checking
performance
checking
1. Select the following group
and subjects.
Group : LAMP
Subject : OFF
Group : LAMP
Subject : OFF
22
Adjustment of
AD Brightness
AD Brightness
1. Select the following group
and subject.
Group : AD
Subject : R-Bright
Group : AD
Subject : R-Bright
G-Bright
B-Bright
B-Bright
1. Check the fixed value.
Fixed value
: 63
Click on the first or last page to see other PG-MB60X (serv.man12) service manuals if exist.