Lamp Replacement Procedure
Version 1.4
Issue 04/2006
Issue 04/2006
12
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
3.
Remove the lamp unit cover.
•
Turn over the projector, and loosen the user
service screw that secures the lamp unit cover.
Then slide the cover in the direction of the arrow.
service screw that secures the lamp unit cover.
Then slide the cover in the direction of the arrow.
4.
Remove the lamp unit.
•
Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of
the arrow.
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of
the arrow.
5.
Insert the new lamp unit.
•
Press the lamp unit firmly into the lamp unit
compartment. Fasten the securing screws.
compartment. Fasten the securing screws.
6.
Replace the filter/lamp unit cover.
•
Align the tab on the filter/lamp unit cover (1) and
place it while pressing the tab (2) to close it.
Then tighten the user service screw (3) to
secure the filter/ lamp unit cover.
place it while pressing the tab (2) to close it.
Then tighten the user service screw (3) to
secure the filter/ lamp unit cover.
Note
•
If the lamp unit and filter/lamp unit cover is not
correctly installed, the power will not turn on,
even if the power cord is connected to the
projector.
correctly installed, the power will not turn on,
even if the power cord is connected to the
projector.