PG-M25XE (serv.man38). Intermittent start-up shut down (locks up) - Sharp Projector Technical Bulletin (repair manual). Page 6

Read Sharp PG-M25XE (serv.man38) Technical Bulletin online

LV064
Sharp Electronics (UK) Ltd., Technical Services Group
2-3.  Checking the installation of driver
(1)  Click the Windows “Start” button and select “Setting” and then “Control Panel”.
(2)  Double click “System”.
(3)  Select the “Device Manager” tab, and then click the [+] button in the
“Ports(COM & LPT)”.
(4)  Check that the “Cypress USB-> COM device” and “Cypress Virtual Port” are
displayed.
2-4. Confirming the COM port assigned
(1)  Start the Tera Term Pro from “Start” button. Select “Programs” and then “Tera
Term pro”.
Note: It is not necessary to change the default communication settings on the
Tera Term Pro. If it is set the different settings, restore it to the default
communication settings. To check the communication settings, select the “Set-
up” from the menu and then select “Serial port”.
Default communication settings:
Baud rate
9600
Data
8 bit
Parity
none
Stop
1 bit
(2)  If the “Tera Term: New connection” dialog box appear, select “Serial” and
select “COM1” in “Port” list, and then click “OK”.
If the “Tera Term:Error” dialog box appear, click ”OK” and then proceed in the
next step.
Page of 34