Read Sharp PG-M15 (serv.man3) Service Manual online
25
PG-M15X
PG-M15S
AN-M15T
OPTICAL ADJUSTMENT AND MEASURING
1. Adjustment of Color Wheel Sensor
»
Adjustment needed
1. When the color wheel unit has been replaced.
2. When the color wheel sensor has been replaced.
3. When the optical drive unit has been replaced (If a deviation from normal setting is found).
1. When the color wheel unit has been replaced.
2. When the color wheel sensor has been replaced.
3. When the optical drive unit has been replaced (If a deviation from normal setting is found).
»
Tools Required
1. Personal computer (run on Windows 95/98)
2. RGB cable
1. Personal computer (run on Windows 95/98)
2. RGB cable