Read Sharp PG-M10SE (serv.man22) Technical Bulletin online
LV058
Sharp Electronics (UK) Ltd., Technical Services Group
a. Confirm that the status is“13845.547”, after rewriting the firmware
b. Make a reset in each “RGB”, “VIDEO”, “S-VIDEO” and “Y Pb Pr” mode.
b. Make a reset in each “RGB”, “VIDEO”, “S-VIDEO” and “Y Pb Pr” mode.
Method of reset:
After selecting the mode, select “RESET” and double-press “ENTER” key on the
back of remote control.
After selecting the mode, select “RESET” and double-press “ENTER” key on the
back of remote control.
The rewriting of firmware is completed.
Next, initialise the data of A/D converter according to the attachement-2 of LV-
058.
Next, initialise the data of A/D converter according to the attachement-2 of LV-
058.
d. Click “Read” button and the PC will read projector’s setting.
e. Check that the Status(firmware version).
e. Check that the Status(firmware version).
In case of PG-M10SU/PG-M10SE: “SVGA : 13945.547”
In case of PG-M10XU/PG-M10XE: “XGA : 13845.547”
If the PC will not start reading the projector’s setting even if you click
“Read” button, check the “Baud” and “Comm” setting again.
In case of PG-M10XU/PG-M10XE: “XGA : 13845.547”
If the PC will not start reading the projector’s setting even if you click
“Read” button, check the “Baud” and “Comm” setting again.