PG-F312X (serv.man5). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 4

Read Sharp PG-F312X (serv.man5) Service Manual online

XR-32S/XR-32X/PG-F212X/PG-F312X
5 – 4
Power supply PWB check
                      
Is 13 V applied to pins (2), (3) and (4) 
of the connector P704?
NO
YES
Does the lamp turn on?
YES
Check the main PWB.
                      
NO
Are connectors P704 and CN901 fully 
inserted?
NO
Securely insert the connectors.
YES
Is DC voltage of 380 V applied to both 
ends of C740?
NO
Is pin (11) of the connector P704 at 
“H”?
NO
Check the main PWB.
YES
YES
Check peripheral circuits of IC707.
Is F705 in the OPEN status?
NO
Is LAMP-EN/SYNC signal properly 
sent to pin (14) of the connector 
P704?
(Refer to the waveform chart 
.)
NO
Check the main PWB.
YES
YES
Check circuits F705 and after or 
replace F705.
Are GATE waveforms of Q901 appro-
priate?
(See waveform diagram 
.)
NO
Check the ballast PWB.
                   
                    
Are connectors P701 and P702 fully 
inserted?
NO
Securely insert the connectors.
YES
Is AC voltage between 100 - 240 V 
applied to both ends of C702?
NO
Replace F701.
YES
Is the bimetal broken?
(Connection between 1 and 2 of 
P702)
NO
Press the red button on the bimetal.
YES
Is R729 open?
NO
Is F704 open?
NO
Check peripheral circuits of IC704.
YES
YES
Check that P704 connector pin (11) 
is at “H”. Replace R729.
Replace F704.
Check that the power supply FAN 
FB and FC are not stopped.
1
1
6
1
Page of 9
Display