PG-F312X (serv.man5). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 3

Read Sharp PG-F312X (serv.man5) Service Manual online

XR-32S/XR-32X/PG-F212X/PG-F312X
5 – 3
DMD system check
                                   
Check P2501 for breakage and solder crack and peripheral resis-
tance for solder crack.
                                   
Check SC9101 on the DMD PWB for breakage and solder crack.
                                   
Is there any vertical stripe (block noise) on the Screen?
YES
The main PWB and DMD PWB are in poor contact.
Check the contact surface for dirt and smear.
Check the DMD connector for breakage.
Reassemble the DMD, optical mechanism, and DMD PWB.
                                   
NO
Is the screen all black?
NO 
                                    
YES
Is 12.5 V applied to IC3803 pin (2) and 1.8 V to 
TL3809?
NO
Check IC3803, IC2205, and their peripheral circuits.
                                    
YES
Is 400 MHz on IC2201 pin (26) and pin (27)?
NO
Check IC2201 and peripheral circuits.
                                    
YES
Is 320 MHz on IC2204 pin (13) and pin (14)?
NO
Check IC2204 and peripheral circuits.
                                    
YES
Is approx. 8 V applied to TL9303 on the DMD PWB?
        NO
YES
Is approx. 26 V applied to TL9301 on the DMD PWB?
NO
Check IC9301 and peripheral circuits.
YES
        NO
Is approx. -26 V applied to TL9302 on the DMD PWB?
YES
The main PWB and DMD PWB are in poor contact.
Check the contact surface for dirt and smear.
Check the DMD connector for breakage.
Reassemble the DMD, optical mechanism, and DMD PWB.
Page of 9