18
PG-C30XE
R-LCD
B-LCD
Lock screw "a"
Lock screw "c"
Notch and 
hole "c"
Notch and 
hole "b"
Lock screw "c"
G-LCD
G-LCD
Lock screw "b"
Notch and hole "c"
Notch and hole "a"
Lock screw "d"
Lock screw "d"
R·B-LCD panel 
mounting screws
(four screws)
R·B-LCD
SIDE VIEW (from inside)
SIDE VIEW (from outside)
TOP VIEW
SIDE VIEW
G-LCD panel 
mounting screws
Eccentric cam
(Y direction adjustment)
Eccentric cam
(X direction adjustment)
Eccentric cam
(
θ
Z direction adjustment)
(four screws)
4. With the G-LCD panel's screen center as refernce, adjust the R-LCD and B-LCD panels.
5. Finally tighten up the convergence lock screw "d".
Notes :
1
The eccentric cam is used for convergence adjustment.
This means that the cam's turning and the linear movement are not always uniform.
2
This model is not equipped with the LCD image adjustment mechanism. This is because the cross-dichroic
prism is used for image formation. When the LCD panels all get into best focus, the images are almost
completely converged.
Convergence and Focus Adjustments Mechanism