LV047
Sharp Electronics (UK) Ltd., Technical Services Group
Modification of PC I/F unit
Figure 2
Remove the 0 Ohm resistors, FL46 and R235.
Change a crystal (X8005) to 18.75MHz type (
9DK001-80023).