Read Sharp PG-C30XE (serv.man18) Technical Bulletin online
LV047
Sharp Electronics (UK) Ltd., Technical Services Group
Modification of PC I/F unit
Figure 1
When installing the system software to the unit,
set the S1 switch to the WRITE mode.
set the S1 switch to the WRITE mode.
Add a 15mm lead wire (9DK001-99046) between TL616 and TL59.
Do not put the lead wire on the ICs.
Do not put the lead wire on the ICs.