PG-C20XE (serv.man5). Section 2 - Service Manual Text - Sharp Projector Service Manual (repair manual). Page 19

Read Sharp PG-C20XE (serv.man5) Service Manual online

19
PG-C20XU
PG-C20XE
AN-Z7T
Resetting the TOTAL LAMP TIMER
1
Connect the power cord.
Reset the lamp timer.
1
Press KEYSTONE 
'
 and
KEYSTONE 
"
 on the projector at
the same time.
2
Press INPUT and AUTO SYNC on
the projector at the same time.
3
Press AUTO SYNC and MENU on
the projector at the same time.
Plug the power cord into the AC
socket of the projector.
LAMP 0000H
LAMP 0000H
 is
displayed, indicating that
the lamp timer is reset.
2
INPUT
BACK
ENTER
MENU
AUTO SYNC
1
3
2
CAUTION
Intense light hazard. Do not attempt to look into the aper ture and lens while the projector is operating.
As the usage environment can vary significantly, the projector lamp may not operate for 1,000 hours.
"1,000 hours" above indicates average life span and should be used for r eference only. This is different than the warranty period.
For safety, the power will not be tur ned on from the fourth times when turning on the power without changing the lamp after use  for 1,000
hours.
Problem
Maintenance Indicator
Condition
Possible Solution
TEMPERATURE
WARNING
indicator
The internal
temperature is
abnormally high.
Blocked air intake.
Relocate the projector to an area with proper
ventilation.
Clean the filter.
Clogged air filter.
Cooling fan br eakdown.
Internal circuit failure.
Take the projector to your nearest Authorized
Sharp Industrial LCD Products Dealer or
Service Center for repair.
Cooling down.
Wait until the indicator stops flashing and
turns off.
The indicator flashes in
red.
LAMP
REPLACEMENT
indicator
The lamp does not
illuminate.
Burnt-out lamp.
Lamp cir cuit failure.
Carefully replace the lamp. 
Take the projector to your nearest Authorized
Sharp Industrial LCD Products Dealer or
Service Center for repair.
The lamp requires
replacement.
Lamp has been used for
over 900 hours.
The filter cover is open.
Securely install the filter cover.
The indicator flashes in
red when the projector
is on.
POWER indicator
Resetting the total lamp timer
When replacing the lamp, reset the total lamp timer in the procedure below.
Light source (lamp)
The lamp used for light source has a service life of about 1,000 hours. If the total operating time exceeds 900
hours, replace the lamp with new one (separately sold) as soon as possible. However, if the image becomes
dim or the colors get less crisp even before the total operating time does not exceeds 900 hours, also replace
the lamp. The lamp's total operating time can be checked on the screen. If noticeable color irregularities are
found after replacing the lamp, make the color irregularity correction on page 28.
Replacing the air filter
Just when replacing the lamp, replace also the air filter with the one that comes with the lamp replacement kit.
1
2
1
2
r
1.Disconnect the power
cord.
Unplug the power cord
from the AC socket.
2.Remove the filter cover.
Turn over the projector.
Press the tab and remove
the filter cover in the direc-
tion of the arrow.
3.Remove the air filter.
1
Remove the air filter
stopper.
2
Remove the air filter.
4.Replace the air filter.
1
 Put the new air filter
into position.
2
 Put the air filter stopper
back into position.
5.Replace the filter cover.
Insert the tab on the end of
the filter cover into the filter
cover opening and press
the filter cover into
position.
Page of 30
Display

Click on the first or last page to see other PG-C20XE (serv.man5) service manuals if exist.