15
PG-C20XU
PG-C20XE
AN-Z7T
Intake fan unit
Remote control 
receiver PWB
Temperature sensor
Output PWB
Grounding spring
3-2
3-4
3-3
3-1
3-1
Electrostatic sheet
(PG-C20XU Only)
(P1702)
(P1707)
(P1703)
(P1705)
(SC1102)
(SC1202)
(SC1302)
(P1601)
(P1708)
(P1706)
(P1704)
(P1602)
(P1701)
3. Removing the output PWB unit, remote control receiver PWB unit and intake
fan unit
3-1. Remove the five lock screws (yellow) from the output PWB unit.  Remove the grounding spring and the
electrostatic sheet (PG-C20XU only).
3-2. Lift the output PWB unit, disconnect the connectors and lift up the output PWB unit.
3-3. Remove the two lock screws (black) from the intake fan unit and detach both the intake fan unit and the
temperature sensor.
3-4. Unhook the claws of the intake fan unit off the remote control receiver PWB unit, and detach this unit.