Read Sharp MX-XB17 Service Manual online
MX-FX13 TROUBLE CODE LIST 5 - 1
[5] TROUBLE CODE LIST
1. FAX-related service call error
2. Communication result code
Described on the communication report table, the communication
management table, and the protocol communication report table
when communication is completed.
management table, and the protocol communication report table
when communication is completed.
A. Composition of communication report code
Communication result X X
(X X X X)
Upper 2 digits of a communication result code: Communication
report code of 00 - 90 (Refer to the list of communication report
codes.)
report code of 00 - 90 (Refer to the list of communication report
codes.)
Lower 4 digits of a communication result code: Codes used by ser-
viceman.
viceman.
Note) Communication report sub code 1 and sub code 2 are in hexa-
decimal. (The others are in decimal.)
<Communication result code list>
(Note) For result codes 16 - 31, V.34 mode communication.
For 32 or later, refer to the table below.
< Communication result code list>
MAIN
SUB
Conditions
F6
00
FA X b o a r d
c o m m u n i c a -
tion trouble
c o m m u n i c a -
tion trouble
When sending cannot be made
due to buffer over.
due to buffer over.
10
FAX hard error
When one of the following items
is detected.
is detected.
Page Memory Error/FAX Board
Error/ROM Error/RAM Error/
Flash ROM Error.
Error/ROM Error/RAM Error/
Flash ROM Error.
80
FA X b r e a k
error
error
When an error is detected in the
IO ASIC serial controller.
IO ASIC serial controller.
81
FA X p a r i t y
error
error
82
FA X o ve r r u n
error
error
84
FA X f ra m i n g
error
error
88
FAX interface
error
error
There is no response of data
from the machine for 30 sec or
more.
from the machine for 30 sec or
more.
97
C o m b i n a ti o n
error between
t h e FA X u n i t
and the main
unit
error between
t h e FA X u n i t
and the main
unit
When this fax unit is installed to
the machine that can not install
this.
the machine that can not install
this.
99
FAX language
error
error
When the TEL/LIU PWB for EX
Japan is operated under the set-
ting for Japan.
W h e n t h e T E L / L I U P W B fo r
Japan is operated under the set-
ting for EX Japan.
Japan is operated under the set-
ting for Japan.
W h e n t h e T E L / L I U P W B fo r
Japan is operated under the set-
ting for EX Japan.
When this fax unit is installed to
the machine that can install only
AR-FX11.
the machine that can install only
AR-FX11.
U1
03
FA X b a t t e r y
error
error
When the battery voltage on the
FAX PWB falls.
FAX PWB falls.
Top 2 digits
Communication report sub code 1 (Refer to
the list of communication sub code 1.)
the list of communication sub code 1.)
Bottom 2 digits
Communication report sub code 2 (Refer to
the list of communication sub code 2.)
the list of communication sub code 2.)
Result
code
Final reception signal
(Transmitting side)
Final reception signal
(Receiving side)
0
Abnormal signal
Abnormal signal
1
NSF, DIS
(SID), (SUB), NSS, DCS
2
CFR
(PWD), (SEP), NSC, DTC
3
FTT
EOP
4
MCF
EOM
5
PIP, PIN
MPS
6
RTN, RTP
PRI-Q
7
No signal, DCN
DCN
8
PPR
PPS-EOP
9
PPS-EOM
10
PPS-MPS, PPS-NULL
11
RNR
RR
12
CTR
CTC
13
ERR
EOR-Q
14
PPS-PRI-Q
15
16
Abnormal signal
Abnormal signal
17
NSF, DIS
SID, SUB, NSS, DCS
18
CFR
PWD, SEP, NSC, DTC
19
FTT
PPS-EOP
20
MCF
PPS-EOM
21
PIP, PIN
PPS-MPS, PPS-NULL
22
RTN, RTP
PRI-Q
23
No signal, DCN
DCN
24
PPR
25
RNR
RR
26
CTR
CTC
27
ERR
EOR-Q
28
PPS-PRI-Q
29
V.8 Phase-1
V.8 Phase-1
30
V.8 Phase-2
V.8 Phase-2
31
V.8 Phase-3
V.8 Phase-3
Result code
(Communica-
tion result)
Communica-
tion report
result
column
Communication interruption
content
0 – 31
R e fe r t o th e
p r e v i o u s
table.
p r e v i o u s
table.
Depends on the communication
disconnection position. For 16 or
later, V.34 mode communication.
disconnection position. For 16 or
later, V.34 mode communication.
33
Busy
The calling side cannot connect
the line with the other party.
the line with the other party.
34
Cancel
When a communication interrup-
tion command is delivered during
t r a n s m i s s i o n o r r e c e p t i o n ,
<Send/Receive/Poll/Bulletin>
tion command is delivered during
t r a n s m i s s i o n o r r e c e p t i o n ,
<Send/Receive/Poll/Bulletin>
W h e n th e op e r at io n is in t er -
rupted by the stop key.
rupted by the stop key.
35
Power OFF
When the power is cur off during
sending or receiving, <Send/
Receive/Poll/Bulletin>
sending or receiving, <Send/
Receive/Poll/Bulletin>
38
R e c e p t i o n
memory over
memory over
When memor y is over during
reception, <Receive/Poll>.
reception, <Receive/Poll>.
When printing cannot be per-
formed during reception due to
inhibition of proxy reception,
<Receive/Poll>
formed during reception due to
inhibition of proxy reception,
<Receive/Poll>
Result
code
Final reception signal
(Transmitting side)
Final reception signal
(Receiving side)
Click on the first or last page to see other MX-XB17 service manuals if exist.