Read Sharp MX-PEX2 (serv.man2) Service Manual online
8
Accessing the Fiery X3eTY2
T
O
ACCESS
AND
OPEN
THE
F
IERY
X3
E
TY2
1.
Remove all external cables that are connected to the Fiery X3eTY2.
2.
Loosen the two upper mounting screws that secure the Fiery X3eTY2 to the back of the
MFP (see Figure E).
MFP (see Figure E).
Loosen, but do not remove, the upper mounting screws.
3.
Remove the two lower mounting screws that secure the Fiery X3eTY2 to the MFP.
4.
Lift up to release the Fiery X3eTY2 from the upper mounting screws. Remove the
Fiery X3eTY2 from the MFP.
Fiery X3eTY2 from the MFP.
F
IGURE
E
Removing the Fiery X3eTY2 from the MFP
Lift Fiery X3eTY2 to clear
upper mounting screws.
upper mounting screws.
Upper mounting screw
(1 of 2)
(1 of 2)
Lower mounting screw
(1 of 2)
(1 of 2)
Slotted hole (1 of 2)
N
OTE
:
The exact mounting
location of the
Fiery X3eTY2
on the MFP may differ from
that shown in this figure.
that shown in this figure.
Click on the first or last page to see other MX-PEX2 (serv.man2) service manuals if exist.