MX-PEX1 (serv.man14). Fiery PEX1 Colour Guide - Sharp Copying Equipment User Guide / Operation Manual. Page 97

Read Sharp MX-PEX1 (serv.man14) User Guide / Operation Manual online

C
OLOR
 M
EASUREMENT
 I
NSTRUMENTS
97
Using the ES-1000 
The ES-1000 is a hand-held 
spectrophotometer
 that measures the 
spectral light
 reflected 
from printed output and other colored materials. Since the ES-1000 accurately measures 
both the 
density
 and color of printed output, it is an effective tool for calibrating the 
Fiery X3eTY2.
The ES-1000 is available as a separately purchased option.
Setting up the ES-1000
To use the ES-1000 for calibration purposes, you must set it up for use with your computer. 
For complete instructions on setting up and calibrating the ES-1000, see the documentation 
that accompanies the ES-1000.
The following illustration shows the different parts of the ES-1000.
Calibrating the ES-1000
When you place the ES-1000 in the calibration cradle, white point calibration is used to 
calibrate the spectrophotometer. Make sure the sample aperture is in full contact with the 
white tile on the calibration cradle.
1
Measure button
2
Sample aperture
3
White tile reference
4
Cradle
1
2
3
4
Page of 104