MX-M950, MX-MM1100 (serv.man40). Section 9 Maintenance - Sharp Copying Equipment Service Manual (repair manual). Page 81

Read Sharp MX-M950 / MX-MM1100 (serv.man40) Service Manual online

MX-M1100  MAINTENANCE  9 – 81
22) Remove the snap band (a), and disconnect the connector (b).
Remove the screw (c), and remove the double feed detection
unit (d).
23) Remove the E-ring (a), and remove the No. 1 resist roller (Idle)
(b).
24) Clean the No. 1 resist roller (a) at every 500K.
25) Disconnect the connector (a). Remove the screw (b), and
remove the document tray unit (c). Clean the transport section
of the document tray unit (c) at every 500K.
26) Check the discharge brush (a) at every 500K. Clean the paper
exit roller (b) at every 500K.
27) Remove the screw (a) and the step screw (b), and remove the
paper guide (c). Clean the paper guide (c) at every 500K.
b