MX-M850 (serv.man38). Section 8 Self Diagnostics Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 32

Read Sharp MX-M850 (serv.man38) Service Manual online

MX-M1100 SELF DIAG AND TROUBLE CODE  8 – 32
 
U6-68
Manual feed tray paper feed position
abnormality
 
U6-69
Manual feed tray lift-up trouble
 
U9-00
Communication trouble between the
controller and the operation
 
UC-02
CPT-ASIC abnormality
 
UC-12
CPT-ASIC abnormality 
(DSPF detection)
 
UC-20
Anti copy module trouble
 
UC-21
The DOCC (Document control) PWB is
not detected
 
UC-22
CPT PWB is not detected.
 
UC-30
Anti copy module trouble 
(DSPF detection)
 
UC-31
The DOCC (Document control) PWB is 
not detected. (DPSF PWB side)
Detail
When the lift-up operation is started, the upper limit 
sensor is turned OFF before the pick-up SOL is turned 
ON. (Normally the upper limit sensor is turned OFF only 
after turning ON the pick-up SOL.)
Section
PCU
Cause
Sensor abnormality, connector and harness connection 
trouble, PWB trouble.
The pick-up roller is kept in the lower position 
mechanically. 
Check & 
Remedy
Use Sim. 4-2 and Sim. 4-3 to check the operation of the 
upper limit sensor and the lift-up operation, and check 
the wiring. 
Detail
When lifting up, the upper limit is not detected within the 
specified time (10 sec)
Section
PCU
Cause
Upper limit sensor abnormality, tray lift-up motor lock, 
connector/harness connection trouble, PWB trouble.
Check & 
Remedy
Use Sim. 4-2 and Sim. 4-3 to check the operation of the 
upper limit sensor and the lift-up operation, and check 
the wiring. 
After making the countermeasure for the trouble 
section, use Sim. 15 to cancel the trouble. 
Detail
Communication establishment error / Framing / Parity / 
Protocol error
Section
ICU
Cause
Slave unit PWB connector connection trouble.
Harness trouble between the slave unit PWB and the 
ICU PWB.
Connector pin breakage of the mother board of the 
slave unit PWB.
Check & 
Remedy
Check connection of the connector and the harness 
between the slave unit PWB and the ICU PWB. 
Check the earth wire of the machine. 
Detail
Access error to the CPT-ASIC 
(The ASIC does not operate normally)
Section
SCU
Cause
B to B connector connection abnormality.
SCU PWB abnormality.
CPT-ASIC abnormality.
Check & 
Remedy
Check the B to B connector. 
Replace the SCU PWB, or replace the option PWB. 
Detail
Access abnormality to CPT-ASIC 
(When ASIC does not operate normally)
Section
SCU
Cause
B to B connector connection abnormality.
DSPF PWB abnormality.
CPT-ASIC abnormality
Check & 
Remedy
Check the B to B connector. 
Replace the DSPF PWB, or replace the option PWB. 
Detail
Communication error between the SCU and the DOCC.
Communication test error when turning on the power or 
after canceling the exclusive simulation. 
Section
SCU
Cause
Contact trouble or disconnection of the connector and 
the harness. 
Control PWB (SCU) trouble or DOCC PWB trouble. 
Malfunction due to noises.
Check & 
Remedy
Turn OFF / ON the power to cancel.
Check the connector and the harness of the 
communication line.
Replace the SCU PWB or replace the DOCC PWB. 
Detail
The DOCC (Document control) PWB is not detected in 
the DSK model
Section
ICU
Cause
The DOCC (Document control) PWB is not installed in 
the DSK model. Connection detection signal trouble. 
Check & 
Remedy
Check the connection detection signal of the DOCC 
(Document control) PWB, or replace the PWB. 
Detail
The CPT PWB is not detected under the color kit enable 
state
Section
ICU
Cause
The CPT PWB is not installed under the color kit enable 
state, or the connection detection signal trouble. 
Check & 
Remedy
Check the connection detection signal of the CPT PWB, 
or replace the PWB.
Detail
Access abnormality to DOCC-ASIC 
(when ASIC does not operate normally)
Section
SCU
Cause
B to B connector connection abnormality.
DSPF PWB abnormality, DOCC-ASIC abnormality.
Check & 
Remedy
Check the B to B connector. 
Replace the DSPF PWB, or replace the option PWB.
Detail
DOCC (document control) PWB cannot be detected in 
the DSK model
Section
ICU
Cause
DOCC (document control) PWB is not installed in the 
DSK model, or the connection detection signal trouble. 
Check & 
Remedy
Check the connection detection signal of the DOCC 
(document control) PWB, or replace the PWB.