MX-M850 (serv.man20). Details of Each Section - I Photoconductor Section - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp MX-M850 (serv.man20) Service Manual online

MX-M1100  PHOTOCONDUCTOR SECTION  i – 9
8)
Hold the handle (a), and pull out the process unit (b) until it
stops.
9)
Hold the green label section (a) on the process unit frame, and
lift it up to remove completely.
a. Process control sensor / Discharge lamp
1)
Remove the process unit.
2)
Remove the OPC drum unit.
3)
Disconnect the connector (a), and remove the screw (b). 
Remove the process control sensor (c).
4)
Remove the blue screw (a), and remove the cover (b).
5)
Disconnect the connector (a), extend the pawl (c), and remove
the discharge lamp (b).
* Be careful not to break the pawl. (c).
b. Temperature humidity sensor 1 / Surface potential sensor / 
PTDL PWB
1)
Remove the process unit.
2)
Remove the OPC drum unit.
3)
Remove the screw (a), and remove the cover (b).
a
b
a
a
a
b
c
a
b
a
b
c
b
a
a
b