How to Place WEB Tension Spring 
 
  (1) Remove the WEB roller fixing plate.         (2) Attach the WEB tension spring to the WEB roller side. 
    
    
    
    
    
      
      
      
      (*Be careful about the direction of this attachment.) 
    
    
    
    
    
    
    
    
    
        
    
    
    
    
(3) After the WEB roller fixing plate is placed, have the foot of the WEB tension spring touched to the WEB  
     tension shaft. 
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
How to Attach WEB Tension Spring: 
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
 
 
 Note: 
 If the fusing unit is installed with the foot of the WEB
 tension spring placed upward, the surface of the 
lower 
WEB roller fixing plate 
 Attach this spring with the side of the 
foot 
Foot of WEB tension spring 
WEB tension shaft 
Lower roller 
 The foot of WEB tension spring 
being 
WEB tension shaft 