Read Sharp MX-M364N / MX-565N Handy Guide online
Electrical
18
SHARP
Document Solution Centre
High Voltage Settings
Note: The adjustment value of each colour mode is specified on the information label attached to the
MC/DV High Voltage Power PWB.
Using Simulation 8-01 (DV Bias Setting) & Sim 8-02 (MC Grid Bias Setting), enter the values
specified, especially after replacing the PCU PWB, EEPROM or following U2 trouble.
specified, especially after replacing the PCU PWB, EEPROM or following U2 trouble.
DV BIAS VOLTAGE – SIMULATION 08-01
Item
Mode
Adjustment Range
Actual Voltage
MX-M365N
MX-M465N
MX-M565N
Middle
Speed
DV Bias Voltage
K
0 - 700
-475 +/- 5V
-475 +/- 5V
-475 +/- 5V
Low
Speed
DV Bias Voltage
K
MAIN CHARGE GRID VOLTAGE – SIMULATION 08-02
Item
Mode
Adjustment Range
Actual Voltage
MX-M365N
MX-M465N
MX-M565N
Middle
Speed
MC Grid Voltage
K
150-850
-665V +/- 5V -670V +/- 5V -670V +/- 5V
Low
Speed
MC Grid Voltage
K
-665V +/- 5V -665V +/- 5V -665V +/- 5V