MAINTENANCE 
SHARP 
 
10
 
MAINTENANCE INDICATIONS: 
 
DK 
OPC DRUM (Counter) has reached  
the specified life. 
Replace OPC Drum 
Process 
Section 
(Drum) 
 
VK 
BLACK DEVELOPER (Counter) has reached 
the specified life. 
Replace Developer. 
Process 
Section 
(Developer) 
 
FK1 
FUSING ROLLER Print Counter has reached 
the specified limit.
 
Replace Upper Heat  
Roller Kit 
Fuser 
Section 
FK2 
PRESSURE ROLLER Print Counter has 
reached the specified limit. 
Replace Lower Heat 
Roller Kit 
 
TK 
TRANSFER UNIT Counter has reached  
the specified limit. 
Replace Transfer Roller 
Unit 
Transfer 
Section 
 
TA 
Maintenance [All] Counter has reached specified limit 
 
 
STARTING POWDER: 
 
The following starting powder should be applied to the relevant consumable item during maintenance:‐ 
 
Starting Powder 
OPC Drum 
Transfer Roller Unit 
MX‐M266N 
MX‐M316N 
Apply CKOG‐0345DS51  
[Yellow Toner] on top of  
UKOG‐0312FCZZ [Stearic Acid] 
None 
 
 
CONSUMABLE SCHEDULE: 
 
 
100K 
150K 
200K 
300K 
400K 
450K 
500K  600K
Process 
MX‐312GV  Developer 
 
X
 
 
 

X
 
 
MX‐312GR  Drum 
 
X
 
 
 

X
 
 
MX‐312DU  Drum frame unit 
X
 
X
 
X
 
 
X
X
 
X
 
MX‐312KA  Maintenance kit 

X
 

X
 
X
 

X
MX‐312TF  Toner filter 
 
 
 
 
 
 
 
 
Fuser 
MX‐313UH  Upper heat roller kit 
X
 
X
 

X
 
X
 

MX‐312LH  Lower heat roller kit 
X
 
X
 
X
 
 
X
 
X
X
 

Transfer 
MX‐312TX  Transfer roller unit 

X
 

X
 

X
 

 
 
 
 
Page of 52