Read Sharp MX-M266N / MX-M316N / MX-M356N (serv.man5) Service Manual online
MX-M316N Dehumidifying heater kit 23 – 5
B. Scanner heater kit installation
(1)
Scanner heater unit assembly
1)
Secure the marking position on the harness of the scanner
heater to the heater fixing plate with the banding band.
heater to the heater fixing plate with the banding band.
2)
Extend the harness, and secure the other position of it with
banding band.
banding band.
3)
Tighten the snap band and cut its tip to approx. 5 mm or less.
Slide the banding band head to the square hole (Part that is
enclosed by the mark).
enclosed by the mark).
NOTE:The banding band head and cut tip must not protrude
behind the heater fixing plate.
(2)
Table glass removal
1)
Remove the glass holder. Remove the table glass and the SPF
glass.
glass.
(3)
Scanner heater unit attachment
1)
Attach the clamp to the scanner frame.
NOTE:When installing, be careful to prevent damage of the
wire.
2)
Remove two screws from the scanner bottom.
3)
Connect the harness of the scanner heater. Attach the scanner
heater unit, and fixing the screw (M3 x 4 Round-tipped).
heater unit, and fixing the screw (M3 x 4 Round-tipped).
1
2
3
2
2
1
Click on the first or last page to see other MX-M266N / MX-M316N / MX-M356N (serv.man5) service manuals if exist.