MX-M260, MX-M260N, MX-M260FG, MX-M260FP (serv.man3). Service Manual (Revised November 2014). - Sharp Copying Equipment Service Manual (repair manual). Page 27

Read Sharp MX-M260 / MX-M260N / MX-M260FG / MX-M260FP (serv.man3) Service Manual online

MX-M260/M310/M260N/M310N  ADJUSTMENTS 5 - 3
6) Measure the distance H between the paper lead edge and the
image print start position. Set the image print start position set
value again.
• 1 step of the set value corresponds to about 0.127mm shift.
• Calculate the set value from the formula below.
99 – H/0.127 (mm) = Image print start position set value
 <H: Print start position measurement value (mm)>
Fit the print edge with the paper edge, and perform the lead
edge adjustment.
Example:99 – 5/0.127 = 99 – 39.4 = about 59
Note: FIf the set value is not obtained from the above formula, per-
form the fine adjustment.
7) Execute SIM 50-1-2 to adjust the main tray lead edge void.
• 1 step of the set value corresponds to about 0.127mm shift.
• Calculate the set value from the formula below.
B/0.127 (mm) = Lead edge void adjustment value 
<B: Lead edge void (mm)>
Example: When setting the lead edge void to 2.5mm:
2.5 /0.127 = about 20
<Adjustment specification>
[H: Print start position measurement value (mm), 
B: Lead edge void (mm)]
(2) RSPF image lead edge position adjustment
1) Set a scale on the OC table as shown below.
Note: Since the printed copy is used as a test chart, put the scale in
paralleled with the edge lines.
2) Make a copy, then use the copy output as an original to make an
RSPF copy again.
3) Check the copy output. If necessary, perform the following adjust-
ment procedures.
4) Execute SIM 50-6.
5) Set the RSPF lead edge position set value so that the same image
is obtained as that obtained in the previous OC image lead edge
position adjustment.
<Adjustment specification>
(3) Rear edge void adjustment
1) Set a scale as shown in the figure below.
2) Set the document size to A4 (8.5" x 11"), and make a copy at
100%.
3) If an adjustment is required, follow the procedures below.
4) Execute SIM 50-1 and set the density mode to DEN-B. The cur-
rently set adjustment value is displayed.
5) Enter the set value and press the start key.
The correction value is stored and a copy is made.
<Adjustment specification>
Item
Content
Setting range
Default
1
TRAY1
1st tray
0-99
53
2
OPTION
Option tray
1-99
3
MANUAL
Manual feed
4
DUPLEX
Back print
Adjustment 
mode
SIM
Set value
Spec value
Setting 
range
Main tray lead 
edge void
50-1
-2
B/0.127
Lead edge void: 
1 – 4mm
Image loss: 3mm 
or less
1 – 99
Print start 
position
50-5
99 – H/0.127
5
10
0mm
0mm
5
10
2.5mm
2.5mm
Adjustment 
mode
SIM
Set value
Spec value
Setting 
range
RSPF 
image lead 
edge 
position
50-6
1 step: 
0.127mm 
shift
Lead edge void:  
1 – 4mm
Image loss: 3mm or less
1 – 99
Adjustment 
mode
SIM
Set value
Spec 
value
Setting 
range
Rear edge 
void
50-1-6
1 step: 0.127mm 
shift
4mm or 
less
1 – 99
A4 (8.5"  x 11")
Paper rear edge
Void amount (Standard value: 4mm or less)
Scale image
Paper rear edge
Page of 127