MX-M260, MX-M260N, MX-M260FG, MX-M260FP (serv.man3). Service Manual (Revised November 2014). - Sharp Copying Equipment Service Manual (repair manual). Page 26

Read Sharp MX-M260 / MX-M260N / MX-M260FG / MX-M260FP (serv.man3) Service Manual online

MX-M260/M310/M260N/M310N  ADJUSTMENTS 5 - 2
(2) MG roller main pole position adjustment
1) Put the developing unit on a flat surface.
2) Tie a needle or pin on a string.
3) Hold the string and bring the needle close to the MG roller horizon-
tally. (Do not use paper clip, which is too heavy to make a correct
adjustment.) (Put the developing unit horizontally for this adjust-
ment.)
4) Do not bring the needle into contact with the MG roller, but bring it
to a position 2 or 3mm apart from the MG roller. Mark the point on
the MG roller which is on the extension line from the needle tip.
5) Measure the distance from the marking position to the top of the
doctor plate of the developing unit to insure that it is 9.1mm.
If the distance is not within the specified range, loosen the fixing
screw A of the main pole adjustment plate, and move the adjust-
ment plate in the arrow direction to adjust.
(3) Developing bias voltage adjustment (SIM 8-1)
1) Execute SIM 8-1.
2) Touch the exposure mode to be changed.
The current set value is displayed.
3) Enter the set value with the 10-key. 
4) Press the [START] key.
Output is made with the entered value, and the display returns to
the original state.
<Adjustment specification>
Min. unit: –10V increment
(4) Grid bias voltage adjustment (SIM 8-2)
1) Execute SIM 8-2.
2) Touch the exposure mode to be changed.
The current set value is displayed.
3) Enter the set value with the 10-key.
4) Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
<Adjustment specification>
Min. unit: –10V increment
B. Mechanism section
(1) Print start position adjustment
1) Execute SIM 50-5.
2) Touch the item to be adjusted.
The item and the currently set value are highlighted. 
3) Press the [P] key.
The display is shifted to the copy menu.
4) Select the paper feed tray, the print density, and the duplex mode.
Enter the adjustment value with the 10-key.
5) Press the [START] key.
Copying is started.
Item
Content
Setting 
range
Default
1
AE (145) 
AE (145mm/s) 
200-
650
450
2
TEXT (145) 
Character 
(145mm/s) 
450
3
TEXT/PHOTO 
(145) 
Character/Photo 
(145mm/s) 
450
4
PHOTO (145) 
Photo (145mm/s) 
450
5
TONER SAVE 
(145) 
Toner save 
(145mm/s) 
400
6
AE (122) 
AE (122mm/s) 
450
7
TEXT (122) 
Character 
(122mm/s) 
450
8
TEXT/PHOTO 
(122) 
Character/Photo 
(122mm/s) 
450
9
PHOTO (122) 
Photo (122mm/s) 
450
10
TONER SAVE 
(122) 
Toner save 
(122mm/s) 
400
9.1mm
A
SIMULATION 8-1
426
1/1
 
DV BIAS COPY SETTING. INPUT VALUE 200-550, AND PRESS
START.
1: AE
426
2: TEXT
450
3: TEXT/PHOTO
450
4: PHOTO
450
5: SUPER/PHOTO
400
6: TONER SAVE
376
 
 
 
 
 
 
 
 
 
 
 
SIMULATION 8-1 
 
Item
Content
Setting 
range
Default
1
AE (145) 
AE (145mm/s) 
350-
750
590
2
TEXT (145) 
Character 
(145mm/s) 
590
3
TEXT/PHOTO 
(145) 
Character/Photo 
(145mm/s) 
590
4
PHOTO (145) 
Photo (145mm/s) 
590
5
TONER SAVE 
(145) 
Toner save 
(145mm/s) 
540
6
AE (122) 
AE (122mm/s) 
590
7
TEXT (122) 
Character 
(122mm/s) 
590
8
TEXT/PHOTO 
(122) 
Character/Photo 
(122mm/s) 
590
9
PHOTO (122) 
Photo (122mm/s) 
590
10
TONER SAVE 
(122) 
Toner save 
(122mm/s) 
540
 
 
 
 
 
 
 
 
 
 
 
SIMULATION 8-2 
 
SIMULATION 50-5
53
1/1
LEAD EDGE ADJUSTMENT(PRINT). INPUT VALUE 0-99, AND PRESS 
START.
1: TRAY1
53
2: OPTION
53
3: MANUAL
53
4: DUPLEX
53
Page of 127
Display

Click on the first or last page to see other MX-M260 / MX-M260N / MX-M260FG / MX-M260FP (serv.man3) service manuals if exist.