MX-LC13N  EXTERNAL VIEW AND INTERNAL STRUCTURE  3 - 2
2.  Switch, Heater
L1DT205
2CS tray lock sensor
Detects lock of the 2CS tray.
L1DT206
2CS upper limit sensor
Detects the upper limit of the 2CS tray.
L1DT207
2CS lower limit sensor
Detects the lower limit of the 2CS tray.
L1DT210
2CS paper top surface sensor
Detects the top surface of paper in the 2CS.
L1DT211
2CS length sensor
Detects the 2CS length.
L1DT212
2CS width sensor 1
Detects the 2CS width.
L1DT213
2CS width sensor 2
Detects the 2CS width.
L1DT214
2CS width sensor 3
Detects the 2CS width.
L1DT215
2CS paper rear edge sensor
Detects paper rear edge of 1CS.
Signal name
Name
Function/Operation
L1DD002
LCT front door open/close detection switch
Detects open/close of the front door.
L1DT101
1CS insertion detection switch 1
Detects insertion of the cassette.
L1DT102
1CS upper limit switch
Prevents the tray from lifting extraordinarily to break the paper feed unit.
L1DT108
1CS reverse rotation detection switch
Detects reverse rotation of the lift motor.
L1DT109
1CS descending switch
Shifts the tray to the paper supply position.
L1DT116
1CS insertion detection switch 2
Detects insertion of the cassette.
L1DT201
2CS insertion detection switch 1
Detects insertion of the cassette.
L1DT202
2CS upper limit switch
Prevents the tray from lifting extraordinarily to break the paper feed unit.
L1DT208
2CS reverse rotation detection switch
Detects reverse rotation of the lift motor.
L1DT209
2CS descending switch
Shifts the tray to the paper supply position.
L1DT216
2CS insertion detection switch 2
Detects insertion of the cassette.
L1HT101
1CS hot-air heater
Makes paper feed air hot.
L1HT201
2CS hot-air heater
Makes paper feed air hot.
L1WH1
1CS dehumidifier heater
Dehumidifies inside of the LCT. (Option)
L1WH2
2CS dehumidifier heater
Dehumidifies inside of the LCT. (Option)
L1WH3
Dehumidifier heater 3
Dehumidifies inside of the LCT. (Option)
L1WH4
Dehumidifier heater 4
Dehumidifies inside of the LCT. (Option)
L1WH5
Dehumidifier heater 5
Dehumidifies inside of the LCT. (Option)
L1WHSW
Dehumidifier heater switch
Manually turns ON/OFF the dehumidifier heater. (Option)
Signal name
Name
Function/Operation
L1DT102
L1HT101
L1HT201
L1WH1
L1WH2
L1WH3
L1WH4
L1WH5
L1DD002
L1DT202
L1DT108
L1DT208
L1DT101
.1WHSW
L1DT109
L1DT209
L1DT201
L1DT116
L1DT216