Read Sharp MX-LC12 (serv.man3) Service Manual online
MX-7040N MX-LC12 (LARGE CAPACITY TRAY) 4 – 2
C. Connection of the main unit and the large
capacity tray unit
1)
Hold the grips of the front and the rear cabinets with both
hands, and lift the left side.
hands, and lift the left side.
2)
Hang the metal fixture of the large capacity tray on the lower
front/rear connecting plate of the main unit side. Push the large
capacity tray onto the main unit and attach it.
front/rear connecting plate of the main unit side. Push the large
capacity tray onto the main unit and attach it.
To confirm that the large capacity tray is locked into place pull
it in the direction of the arrow as shown.
it in the direction of the arrow as shown.
NOTE: If lock is incomplete, when the power switch is turned
on, the message, “Check installation of tray 5” is dis-
played on the operation panel.
played on the operation panel.
NOTE: Push the large capacity tray onto the machine, and
lock it securely.
NOTE: When lifting the LCC, insert fingers firmly into the grip sec-
tions of the front and rear cabinets and install slowly.
NOTE: Turn the lock release screw of the front cover counterclock-
wise to loosen and check that the screw is free.
* If the screw is tight at that time, installation will be incom-
plete.
(1) How to separate the large capacity tray from the
main unit
1)
Turn the lock release screw of the front cover clockwise and
tighten the screw securely to release lock.
tighten the screw securely to release lock.
2)
Then hold the grips of the front and the rear cabinets with both
hands, and lift the left side. The large capacity tray will come
off.
hands, and lift the left side. The large capacity tray will come
off.