No. Item
Details
16 Other
At the timing of sending the Alert Mail of E-mail RIC, the mode to prevent more than one
Alert Mails of the same event from being sent out when warming up from the Energy
Save has been added to the controller SOFT SW.
SIM55-3 SW No. 28 Data 3
0: Allowed: Current operation (Default)
1: Not Allowed
Alert Mails of the same event from being sent out when warming up from the Energy
Save has been added to the controller SOFT SW.
SIM55-3 SW No. 28 Data 3
0: Allowed: Current operation (Default)
1: Not Allowed
17 Other
Modification has been made to change the frequency to obtain the information of the
remaining toner using MIB with SOFT SW.
SIM55-3 SW No. 32 Data 2
0: every 25% (Default)
1: every 5%
remaining toner using MIB with SOFT SW.
SIM55-3 SW No. 32 Data 2
0: every 25% (Default)
1: every 5%