MX-7040N  MX-PN12A/B/C/D (PUNCH MODULE)  15 – 3
B. Connection of connector of the finisher and 
punch unit
1)
Remove the fixing screws, and remove the rear cover.
2)
Connect two connectors of the finisher to the PWB of punch
unit, and fix the harness to the clamp.
C. Install of the connection fixture F/R
1)
Install the connection fixture F to the main unit with the fixing
screws.
2)
Install the connection fixture R to the main unit with the fixing
screws.
D. Check of the connected position of main unit 
and finisher
1)
Engage the finisher that has installed punch unit to the main
unit, and temporarily fix.
NOTE: Insert the rail of the finisher unit into the rail reception
fixture of main unit, fix temporarily.
2)
Check that the center of the screw hole of the punch unit is in
the range of specification of an oval hole of the mounting fix-
ture  in front side of main unit.
MEMO: When not the range of specification, execute the
adjustment procedure of each finisher. If the adjustment is not
required, execute the procedure for touch of the auxiliary
caster with the floor of each finisher.